Seismic performance of beam-column joints with fuse bars under in-plane lateral cyclic loading / Nurfarhana Diyana Abdul Hadi

Abdul Hadi, Nurfarhana Diyana (2021) Seismic performance of beam-column joints with fuse bars under in-plane lateral cyclic loading / Nurfarhana Diyana Abdul Hadi. PhD thesis, Universiti Teknologi MARA.

Abstract

The 2015 Ranau earthquake caused severe damage to the RC beam-column joint of school buildings in the Kundasang region, resulting in a soft-story mechanism. These buildings were designed and constructed using British Standard (BS8110), a non-seismic code of practice. As a solution for this problem, this study assesses the seismic performance of beam-column joints with fuse bars designed using Eurocode 8 and without fuse bars designed using BS8110 for a two-story RC school building prototype. The fuse bars were designed using the Pushover Analysis and incorporated in the seismic beam-column joints as passive energy dissipators to enhance the energy dissipation capacity of the beam-column joints. Three super-assemblages, corner beam-column joint, interior beam-column joint, and exterior beam-column joint with fuse bars, were designed, constructed, and tested under in-plane lateral cyclic loading. The seismic response comparisons between beam-column joints with and without fuse bars were made to establish the effectiveness of fuse bars as energy dissipators in beam-column joints. Subsequently, the global structural response of the two-story RC school building was assessed under eight past earthquake records using the Ruaumoko 2D and Dynaplot Program. The seismic vulnerability and deformation capacity of each joint under moderate and significant earthquake records and DBE and MCE for Malaysia were assessed. The results show that beam-column joints with fuse bars have Ductility Class Medium (DCM). The beam-column joints with fuse bars also have higher stiffness and lateral strength capacity. The effectiveness of the additional damping provided by the fuse bars is adequate in resisting earthquake load with 0.12g PGA and lower. But it is still not sufficient to decrease lateral displacement of the beam-column joints when subjected to 0.214g PGA and above. All three beam-column joints can also sustain under DBE and MCE for Type 1 and Type 2 earthquakes. The findings show that the beam-column joints with fuse bars can withstand the highest recorded earthquake in Malaysia, the 2015 Ranau earthquake with 6.0 magnitude and a peak ground acceleration of 0.12g.

Metadata

Item Type: Thesis (PhD)
Creators:
Creators
Email / ID Num.
Abdul Hadi, Nurfarhana Diyana
2013845868
Contributors:
Contribution
Name
Email / ID Num.
Thesis advisor
Abdul Hamid@Zulkurnail, Nor Hayati (Associate Professor Dr.)
UNSPECIFIED
Subjects: T Technology > TA Engineering. Civil engineering > Structural engineering > Structural design > Structural design for dynamic loads > Earthquake resistant design
Divisions: Universiti Teknologi MARA, Shah Alam > College of Engineering
Programme: Doctor of Philosophy (Civil Engineering)
Keywords: Earthquake; structural damage; seismic design; soft-storey mechanisms; beam-column joint; fuse bars; direct displacement based design; hysteresis loop
Date: October 2021
URI: https://ir.uitm.edu.my/id/eprint/61022
Edit Item
Edit Item

Download

[thumbnail of 61022.pdf] Text
61022.pdf

Download (40kB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:

ID Number

61022

Indexing

Statistic

Statistic details