Abstract

Cementiess hip arthrosplasty is categorized when the surface of the metal parts is porous, and looks like coral and its bond to the femur without any cement between stem and cortical bone. The design of hip prosthesis is believed to be an important factor to minimize the aseptic loosening problems and to encourage long term stability. The objectives of this project are to develop finite element model of intact femur and Total Hip Replacement and to study the stress distribution of cementiess hip arthrosplasty in different design of taper of prosthesis stem. This project is assumed to be static analysis and represent stair climbing analysis for cementiess hip arthorsplasty. The different design of the prosthesis stem are straight, single taper and double taper and based on PERFECTA design. The prosthesis is design to be a generic "high stiffness" and bio compatibility material that is Titanium alloy Ti-6AI-4V. The femur model is fixed at the bottom while 800N and 1250N are applied to the femur that represents the hip contact and abductor muscle, respectively. The effects of stress distribution of the cementiess hip arthrosplasty are described with respect to von mises stress of the analysis. Result shows 45.2MPa, 38.0MPa and 36.4MPa for straight, single and double taper, respectively. Double taper of prosthesis stem produce the best results compare to the other design. Further study on different taper design such as Tri taper are suggested to clarify the effect of the prosthesis tapers.

Metadata

Item Type: Thesis (Degree)
Creators:
Creators
Email / ID Num.
Selamat, Muhamad Firdaus
2006895225
Contributors:
Contribution
Name
Email / ID Num.
Thesis advisor
Abdullah, Abdul Halim
UNSPECIFIED
Subjects: T Technology > TA Engineering. Civil engineering > Mechanics of engineering. Applied mechanics
T Technology > TA Engineering. Civil engineering > Materials of engineering and construction > Physical properties > Surface effects and tests
T Technology > TA Engineering. Civil engineering > Materials of engineering and construction > Cement, lime, mortar, etc.
Divisions: Universiti Teknologi MARA, Shah Alam > Faculty of Mechanical Engineering
Programme: Bachelor Engineering (Hons) Mechanical
Keywords: Cementless, Arthrosplasty, Prosthesis
Date: 2009
URI: https://ir.uitm.edu.my/id/eprint/31576
Edit Item
Edit Item

Download

[thumbnail of 31576.pdf] Text
31576.pdf

Download (100kB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:

ID Number

31576

Indexing

Statistic

Statistic details