Abstract
I-joist component is using the system that involves the using of LVL rubberwood flanges and plywood parallel as web. Both component are combined and must work and act together. The strength will be same with solid wood. The purpose of this testing is to test the strength of I-joist that made from the combination between LVL as flanges and plywood parallel as web by using rubberwood. The sample of i-joist that has the highest modulus of rupture, MOR value was sample LP-3 (27.03 MPa) and the lowest was sample LP-7 (15.91 MPa). Furthermore, the testing was to test the modulus of elasticity true. Test shows the highest value was sample LP-3 (8025.56 MPa) and the lowest was sample LP-I (6628.81 MPa). As a conclusion to this study, flange and web components act together and perform as a system of I-joist.