Civil engineering design project technical report

Noorazam, Damia Izzati Akhtar (2024) Civil engineering design project technical report. [Student Project] (Unpublished)

Abstract

First and foremost, the architectural drawings are important before starting the design process. From architectural drawings, structural drawings can be produced. The placement of column, beam and slab can be identified and evaluated whether it is suitable or not the placement of the structural member. After the placement is identified and evaluated, the size of each structural member can be calculated to make sure that each member can bear the load from the building. Firstly, for slab design, the thickness that has been chosen was 120 mm. The diameter bar proposed was 8 mm and grade concrete that has been chosen was 30 N /mm 2 . This was because since the slab that needs to be designed was big, it needs strong concrete. Since the grade concrete is strong already so the bar size chosen was 8 mm to reduce the cost as the smaller diameter of a bar the lower the price. The thickness of the slab can be considered as thin but from the calculation all of the checking pass and did not fail. Plus, the slab that needs to be designed was on the ground floor where there is no toilet, so a drop of 50 mm does not need to be considered. Next, for beam design, the size of the beam was 150 x 239 mm. The diameter of bar and link was 12 mm and 8 mm respectively. The size proposed was based on the biggest slab that was connected to the beam. The size proposed for bar and link was proposed based on the size of the beam. Based on the calculation, the size proposed, diameter bar and link proposed satisfy requirements for a beam. It can support the load from the slab, brick wall if any, and its self weight to be transported to the column. Other than that, for column design, the size proposed was 300 x 450 mm, the diameter of bar and link was 25 mm and l O mm. The size of column proposed was based on the value of axial loading from roof that the column needs to support. The bar size and link diameter proposed was based on the size of column. From the calculation, the size proposed passed the requirement which was the column must be a short and biaxial column. The column must need to be categorized as short column because the deflection was small and more suitable as the building that needs to be design was only a double story house.

Metadata

Item Type: Student Project
Creators:
Creators
Email / ID Num.
Noorazam, Damia Izzati Akhtar
2021828764
Contributors:
Contribution
Name
Email / ID Num.
Advisor
Yahya, Norrul Azmi
218614
Subjects: T Technology > TH Building construction > Details in building design and construction.Including walls, roofs
T Technology > TH Building construction > Architectural engineering. Structural engineering of buildings
Divisions: Universiti Teknologi MARA, Johor > Pasir Gudang Campus > Faculty of Civil Engineering
Programme: Diploma of Civil Engineering
Keywords: Architectural drawing, Slab design, Beam design, Column design
Date: 2024
URI: https://ir.uitm.edu.my/id/eprint/122953
Edit Item
Edit Item

Download

[thumbnail of 122953.pdf] Text
122953.pdf

Download (153kB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:

ID Number

122953

Indexing

Statistic

Statistic details