Copper, lead and diphenylamine in gunshot residue analysis using screen printed carbon electrode (spce) and gold coated spce / Nurul 'Afiqah Hashimah Mohd Hashim

Mohd Hashim, Nurul 'Afiqah Hashimah (2019) Copper, lead and diphenylamine in gunshot residue analysis using screen printed carbon electrode (spce) and gold coated spce / Nurul 'Afiqah Hashimah Mohd Hashim. Masters thesis, Universiti Teknologi MARA (UiTM).

Abstract

Electrochemical analysis on screen printed carbon electrode (SPCE) is relatively simple, rapid and reliable tool inorganic compound identification such as copper in gunshot residue (GSR). SPCE is specially designed to cope with microvolumes of sample such as GSR sample due to its potential for miniaturization and facility of automation. It would be beneficial for the quantification of copper in GSR for a forensic analyst in the fastest way at the discharging area. The coating of gold on SPCE enhances the voltammetric performances towards detection of copper, lead and diphenylamine. The coupling of voltammetry with gold coated SPCEs allows the onsite preliminary test and improves the conventional method which capable to analyze GSR in the laboratory in the long period and have a risk of sample loss. The gold coated SPCE was swabbed directly on the shooter's arm immediately after discharging a firearm and the sample SPCE was analyzed using cyclic voltammetric method. The electrochemical performances of copper, lead and diphenylamine on bare SPCE and gold coated SPCE using voltammetric method were studied. Gold coated SPCE was characterized and optimized before field work. The voltammetric sensor responded to a series of 1 ppm to 100 ppm of copper solution shows gold coated SPCE increased the percentage of reproducibility about 5 % to 17 % in aspect of current density compared to bare SPCE due to their large effective surface area, effective catalysis and fast mass transport. GSR analysis was performed on Glock, Rifle Stryer AUG-Al and Rifle Colt M16-A1 using cyclic voltammetry and Inductive Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) methods. The results obtained from cyclic voltammetric analysis show sopper concentrations detected in Glock, Rifle Stryer AUG-Al and Rifle Colt M16-A1 were 0.680 ppm, 1.349 ppm and 0.707 ppm respectively while the amounts of copper detected by ICP-OES analysis were 0.724 ppm (Glock), 1.432 ppm (Rifle Stryer AUG-Al) and 0.748 ppm (Rifle Colt M16-A1). The paired Student's t-test indicated that there was no significant difference between the results obtained from both methods at the 94 % confidence level. A p-va\ue of less than 0.05 was considered significant. Therefore, it can be
concluded that the proposed method is reliable and can be successfully applied to the copper determination in GSR analysis.

Metadata

Item Type: Thesis (Masters)
Creators:
Creators
Email / ID Num.
Mohd Hashim, Nurul 'Afiqah Hashimah
2013927273
Contributors:
Contribution
Name
Email / ID Num.
Thesis advisor
Mohd Zain, Prof. Dr. Zainiharyati Mohd Zain
UNSPECIFIED
Divisions: Universiti Teknologi MARA, Shah Alam > Faculty of Applied Sciences
Programme: Master of Science
Keywords: performances of copper, lead and diphenylamine
Date: 2019
URI: https://ir.uitm.edu.my/id/eprint/95908
Edit Item
Edit Item

Download

[thumbnail of 95908.pdf] Text
95908.pdf

Download (167kB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:

ID Number

95908

Indexing

Statistic

Statistic details