Hazardous area classification for wheat flour processing plant / Mohd Aizad Ahmad, Muhammad Naqib Saifullah Noor Azman and Zulkifli Abdul Rashid

Ahmad, Mohd Aizad and Noor Azman, Muhammad Naqib Saifullah and Abdul Rashid, Zulkifli (2021) Hazardous area classification for wheat flour processing plant / Mohd Aizad Ahmad, Muhammad Naqib Saifullah Noor Azman and Zulkifli Abdul Rashid. Malaysian Journal of Chemical Engineering and Technology (MJCET), 4 (2): 12. pp. 172-183. ISSN (e-ISSN): 2682-8588

Abstract

Dust explosion possibly occurs in common unit operations such as mills, grinders, dryers, and other modes of transport. The basic element for the setting of hazardous zone types consist of identifies release sources, determination of classification region of hazardous area, overviewing the basic operation in wheat flour processing plant with their specification requirement and use of a suitable code or calculations to determine area scope. Therefore, this analysis can be more elaborate by classifying the hazardous area into several areas using the International Electro Technical Commission System for Certification to Standards Relating to Equipment for Use in Explosive Atmospheres standard. Thus, wheat flour processing plant area classification can be categorized according to three zones based on the quantity of an explosion into atmosphere and its release frequencies which are zones 20, zones 21, and zones 22. From the results, it can be summarized that zone 20 is almost inside or closer one with the main equipment located near the ignition source which could lead to dust explosion, whereas zone 21 and zone 22 comes after zone 20 which is a less hazardous area as compared to zone 20 areas.

Metadata

Item Type: Article
Creators:
Creators
Email / ID Num.
Ahmad, Mohd Aizad
mohdaizad@uitm.edu.my
Noor Azman, Muhammad Naqib Saifullah
UNSPECIFIED
Abdul Rashid, Zulkifli
UNSPECIFIED
Subjects: T Technology > TJ Mechanical engineering and machinery > Mechanics applied to machinery. Dynamics
T Technology > TJ Mechanical engineering and machinery > Machine design and drawing
Divisions: Universiti Teknologi MARA, Shah Alam > Faculty of Chemical Engineering
Journal or Publication Title: Malaysian Journal of Chemical Engineering and Technology (MJCET)
UiTM Journal Collections: UiTM Journal > Malaysian Journal of Chemical Engineering and Technology (MJCET)
ISSN: (e-ISSN): 2682-8588
Volume: 4
Number: 2
Page Range: pp. 172-183
Keywords: Dust explosion, Hazardous area, Classification
Date: October 2021
URI: https://ir.uitm.edu.my/id/eprint/58910