Abstract
Introduction: The investigation of indoor air quality (IAQ) important to study because IAQ is not new issue in Malaysia. This study aimed to determine the relationship of particulate matter (PM2.5) with Sick Building Syndrome symptoms (SBS) among librarians in two different libraries (old and new building) in UiTM. There are three sampling points selected which have similarity both libraries which consists of recovery room, office and receptionist. 26 librarians from PTAR Shah Alam and 14 librarians from PTAR Puncak Alam were selected to answer the questionnaire. Questionnaire based on Industrial Code of Practice, 2010 was performed to record prevalence of SBS. Methodology: Cross-sectional comparative study designs were used in this study to asses on indoor air quality in two different libraries in Selangor which is old and new libraries at PTAR UiTM and also conduct the survey of Sick Building Syndrome among selected librarian at both libraries. This study involved 40 librarian consists of 26 librarians from PTAR UiTM Shah Alam (old library) and 14 librarians from PTAR UiTM Puncak Alam (new library). The SBS symptoms were assessed by questionnaire of Industry Code of Practice on Indoor Air Quality (2010). IAQ were monitored by using Q-trak (TSI Model 7575) and Dust-trak II aerosol monitor (TSI Model 8531). Results: There was significant higher prevalence of SBS among old building and new building (X2 = 55.441,p< 0.000). Mann Whitney test showed there were significant higher indoor air pollutnts in old building compare to new building : Office; for PM2.5 ( z—1.966, p<0.049), C02 ( z=-0.288, p<0.773), Temperature ( z=- 2.515, p<0.012), Relative humidity ( z=-9.71, p<0.331) : Recovery room; PM2.5( z=- 19.052, p<0.000), C02 ( z=-18.801, pO.OOO), Temperature ( z=-2.501, p<0.012), Relative humidity ( z=-9.961, p<0.337) : Receptionist PM25 ( z=-19.195, p<0.000), C02 ( z=-18.799, p<0.000), Temperature ( z=-5.544, p<0.000), Relative humidity ( z=-2.433,p<0.015). Conclusion: This study suggested that increasing PM2.5, C02, temperature and relative humidity may influence the occurrence of SBS among librarians. A future study is suggested to identify the risk of exposure IAQ level and relationship of SBS.
Metadata
Item Type: | Student Project |
---|---|
Creators: | Creators Email / ID Num. Masri, Nur Afzanizan 2011635706 |
Contributors: | Contribution Name Email / ID Num. Thesis advisor Md.Rashid, Razi Ikhwan UNSPECIFIED Thesis advisor Megat Mokhtar, Megat Azaman UNSPECIFIED |
Subjects: | Z Bibliography. Library Science. Information Resources > Library buildings. Library architecture |
Divisions: | Universiti Teknologi MARA, Selangor > Puncak Alam Campus > Faculty of Health Sciences |
Programme: | Bachelor (Hons.) in Environmental Health and Safety |
Keywords: | Indoor Air Quality (IAQ), Particulate Matter 2.5(PM2.s), new building, old building, Sick Building Syndrome (SBS), C02, Temperature, Relative Humidity |
Date: | 2015 |
URI: | https://ir.uitm.edu.my/id/eprint/36704 |
Download
36704.pdf
Download (160kB)
Digital Copy
Physical Copy
- Koleksi Akses Terhad | PTAR Utama | Shah Alam
- Bilik Koleksi Harta Intelek, Unit Terbitan Bersiri dan Elektronik | PTAR Puncak Alam