Fire simulation protocol and the role of a CFD software / Cliff Bidi

Bidi, Cliff (2004) Fire simulation protocol and the role of a CFD software / Cliff Bidi. Masters thesis, Universiti Teknologi MARA.

Abstract

Current trends in fire safety designs are to depart from conventional prescriptive regulations. This trend towards an engineering or performance-based approach allows for the introduction of more innovative designs. The correct modelling of fire scenarios are central to the implementations of performance-based designs, especially with rapid developments in the field of Computational Fluid Dynamics (CFD) techniques or field models as opposed to zone models which are empirically derived . The purpose of this research is to explore the feasibilities and reliabilities of field modelling techniques in the predictions of fire behaviour and its effects. The three main objectives of this research are: 1. To identify suitable simulation protocols for safe evacuation of occupants, 2. To establish Available Safe Egress Time (ASET) using CFD Software and 3. To identify certain CFD attributes needed to satisfy the above. In the present study a review of prescriptive and engineered system are highlighted. The role of CFD in field modelling has been identified with respect to prediction of various parameters, which affected tenability and the time taken for untenable conditions to prevail for assigned fire sizes. To test the above requirement , various fire scenarios were analysed employing zone models to initially identify input parameters required for the field model. Computation for ASET employing field model is carried out and these results are compared with the Required Safe Egress Time (RSET) computed from existing empirical equations in the literature . CFD results validated the zone models, which are empirically derived . However, it was found that zone models are limited in their applications and for complex geometries the field models can give a better description of fire behaviours. Of interest is the discovery that the prescriptive requirement of 12 airchanges per hour is acceptable in certain instances whilst in another instance it is over prescribed depending on the fire scenario and on the physical size of the room being analysed. CFD software attributes such as appropriateness of turbulence model selected, evidence of grid independence and convergence criteria are investigated. The relevant parameters, which should be included in any field model, are the location of the fire source, dimension and transient conditions of the fire source and its smoke concentration , outlet and inlet boundary conditions and appropriate turbulence model.

Metadata

Item Type: Thesis (Masters)
Creators:
Creators
Email / ID Num.
Bidi, Cliff
UNSPECIFIED
Subjects: T Technology > TJ Mechanical engineering and machinery > Power resources
Divisions: Universiti Teknologi MARA, Shah Alam > Faculty of Mechanical Engineering
Programme: Master of Science in Mechanical Engineering
Keywords: CFD software, Fire simulation, Fire safety
Date: 2004
URI: https://ir.uitm.edu.my/id/eprint/27271
Edit Item
Edit Item

Download

[thumbnail of 27271.pdf] Text
27271.pdf

Download (1MB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:
On Shelf

ID Number

27271

Indexing

Statistic

Statistic details