Validity of selected White Blood Cells (WBC) differential flags of sysmex XE-2100 in Hospital Selayang / Nur Nazihah Md. Yusof

Md. Yusof, Nur Nazihah (2020) Validity of selected White Blood Cells (WBC) differential flags of sysmex XE-2100 in Hospital Selayang / Nur Nazihah Md. Yusof. Masters thesis, Universiti Teknologi MARA (Kampus Sg. Buloh).

Abstract

Automated white blood cells (WBC) differential counts are widely accepted in routine practice, as the accuracy and clinical usefulness have been validated in numerous studies. However, many laboratories still reflexively perform manual WBC differential counts based solely on instrument “flags”. Haematology laboratory of Selayang Hospital has been using a set of criteria for peripheral blood film (PBF) review, which are adapted from international consensus guidelines (2005) but with modification of several parameters, established by our expert opinion by taking into account our local requirements, and our criteria do not include the analyser’s flags. In this study, we determined the validity of selected 5 most common WBC differential related flags in automated full blood count (FBC) analyser Sysmex XE-2100 by correlating the flags with PBF to verify the safety of our PBF review criteria. Overall, 422 flagged samples were selected during the period of study. The results of both automated and manual counting and scanning of the samples were carefully studied and compared. A total of 538 flags were identified, which consist of 216 atypical lymphocyte flags, 196 blasts flags, 48 WBC AbN scattergram flags, 39 NRBC flags, and 39 monocytosis flags. Qualitatively, there was statistically significant towards negative PBF findings for blasts flags in both age group, and monocytosis flags in the children sample, while the flag of atypical lymphocyte in the children’s age group was statistically significant towards positive findings. Quantitatively, there was a statistically significant difference in the mean of automated and manual monocyte counts in both age groups. The underlying disorders of all these true positive and false-positive flags are heterogeneously varied and they were rather inconsistent and inefficient with low specificity. Based on these findings, we agreed to ignore all the flags and report the FBC using the automated count. Although the atypical lymphocyte flag of the paediatric group was statistically significant towards positive PBF findings, we also ignored this flag as the results did not greatly affect the clinical management of the patients. Facing over-flagging of specimens from an automated FBC analyser is a problem in the haematology laboratory, as a flag requires a time-consuming microscopic review of the specimen, which increases the workload of the laboratory personnel, while they constantly under pressure to provide accurate test results to clinicians promptly. Our goal was to develop a system that directed the use of automated and manual WBC differential assessment towards the greatest clinical gain and increased the efficiency of laboratory operations and enabling laboratory personnel to concentrate on tasks that are no achievable through automated methods. Therefore, in the background of our local patient population, we proposed that there is no clinical rationale for reflex manual PBF examination based on instrument flags, and our current criteria for blood smear review are adequate and safe.

Metadata

Item Type: Thesis (Masters)
Creators:
Creators
Email / ID Num.
Md. Yusof, Nur Nazihah
2015985407
Contributors:
Contribution
Name
Email / ID Num.
Thesis advisor
Khalid, Dr. Zalizah
UNSPECIFIED
Subjects: Q Science > QR Microbiology > Immunology
Divisions: Universiti Teknologi MARA, Selangor > Sungai Buloh Campus > Faculty of Medicine
Programme: Master of Pathology (Medical Haematology)
Keywords: White Blood Cells (WBC), Sysmex XE-2100, Hospital Selayang
Date: 2020
URI: https://ir.uitm.edu.my/id/eprint/89036
Edit Item
Edit Item

Download

[thumbnail of 89036.pdf] Text
89036.pdf

Download (169kB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:

ID Number

89036

Indexing

Statistic

Statistic details