MultiPhase pulse flow pump warning system based on movement detection / Mohamad Mazwan Mahat … [et al.]

Mahat, Mohamad Mazwan and Saedon, Dr Juri and Bahsan, Rosnadiah and Makhtar, Ahmad Khushairy (2013) MultiPhase pulse flow pump warning system based on movement detection / Mohamad Mazwan Mahat … [et al.]. In: Optimizing Innovation for Global Commercialization Research, Invention, Innovation Design: RIID 2013. Division of Research, Industrial Linkages and Alumni, UiTM Cawangan Melaka, Alor Gajah, Melaka, p. 25. ISBN 978-967-0637-02-0 (Submitted)

Abstract

This project developed and fabricated a new device that used to solve common problems for heart failure patients. The aim of this project is to obtain the effect of fluid characteristics of pressure and velocity in valve less impedance pump using pulsation flow based on different voltage supply and frequency. When the fluid-filled elastic tube is connected to a tube that has different impedance, net flow in either direction can be induced by periodically pinching the flexible tube asymmetrically from the end. In addition, it is also intended to determine the fluid volume flow rates (ml/min) in elastic tubes based upon different impedance pump pinch parameters (location and width). The input parameters evaluated are pinch frequency, voltage, pinch location, pincher width, elastic tube length and viscosity. This project uses experimental results as the approach to establish the relationship between the parameters. It is found that parameters like flow rate, velocity and pressure increase when the pinch location of the elastic tube is varied. The interaction with the inertia of the returning flow is an important factor determining the average flow for a closed loop system. The final product outcome from this experiment can be used as a model for a new Ventricular Assist Device for cardiac patients. It also can give further explanation about the factors that will influence the characteristics of valve less impedance pump.

Metadata

Item Type: Book Section
Creators:
Creators
Email / ID Num.
Mahat, Mohamad Mazwan
UNSPECIFIED
Saedon, Dr Juri
UNSPECIFIED
Bahsan, Rosnadiah
UNSPECIFIED
Makhtar, Ahmad Khushairy
UNSPECIFIED
Contributors:
Contribution
Name
Email / ID Num.
Director
Omar, Roaimah
UNSPECIFIED
Chief Editor
Abdul Wahab, Shafezah
UNSPECIFIED
Team Member
Sakrani, Siti Najah Raihan
UNSPECIFIED
Team Member
Abd Ghalim, Shahril Anuar
UNSPECIFIED
Team Member
Mahzan, Sulaiman
UNSPECIFIED
Team Member
Md Shah, Mohd Ab Malek
UNSPECIFIED
Team Member
Mohamad, Nur Syuhada
UNSPECIFIED
Team Member
Abdul Batau, Mohd Fajil
UNSPECIFIED
Team Member
Ibrahim, Khalilah
UNSPECIFIED
Designer
Amin Nudin, Anith Liyana
UNSPECIFIED
Designer
Samsuri, Norsharina
UNSPECIFIED
Subjects: R Medicine > R Medicine (General) > Computer applications to medicine. Medical informatics
Divisions: Universiti Teknologi MARA, Melaka > Bahagian Penyelidikan dan Jaringan Industri, UiTM Melaka
Event Title: Research, Invention, Innovation Design (RIID2013)
Event Dates: 16 - 17 Disember 2013
Page Range: p. 25
Keywords: Pulse flow pump; Heart failure; Health
Date: 2013
URI: https://ir.uitm.edu.my/id/eprint/78404
Edit Item
Edit Item

Download

[thumbnail of Abstract Only] Text (Abstract Only)
78404.pdf

Download (1MB)

ID Number

78404

Indexing

Statistic

Statistic details