Raja Arif, Raja Muhammad Aslam
(2021)
Effects of high-temperature operating conditions on the through-plane gas permeability of gas diffusion layers used in PEFCs / Raja Muhammad Aslam Raja Arif.
Journal of Applied Engineering Design & Simulation (JAEDS), 1 (1): 1.
pp. 1-11.
ISSN 2805-5756
Official URL: https://jaeds.uitm.edu.my/
Abstract
In order to simulate the effects of high-temperature operating conditions on the through-plane gas permeability of gas diffusion layers (GDLs) used in polymer electrolyte fuel cells, uncoated and coated GDLs were heated at various temperatures (i.e. 200, 500 and 800 °C). The results show that the through-plane gas permeability of the uncoated GDLs generally increases after higher temperature treatment. However, the coated GDL displays a different trend: the through-plane gas permeability increases with increasing temperature treatment to 200 and 500 °C, but then decreases after heat treatment at 800 and 1000 °C. With the assistance of SEM images, the above results are discussed.
Metadata
Item Type: | Article |
---|---|
Creators: | Creators Email / ID Num. Raja Arif, Raja Muhammad Aslam UNSPECIFIED |
Divisions: | Universiti Teknologi MARA, Shah Alam > Others |
Journal or Publication Title: | Journal of Applied Engineering Design & Simulation (JAEDS) |
UiTM Journal Collections: | UiTM Journal > Journal of Applied Engineering Design & Simulation (JAEDS) |
ISSN: | 2805-5756 |
Volume: | 1 |
Number: | 1 |
Page Range: | pp. 1-11 |
Date: | September 2021 |
URI: | https://ir.uitm.edu.my/id/eprint/66461 |