Gheitasi, A. and Moghavvemi, Mahmoud and Omar, Rosli
(2008)
Implementation of motor current signature analysis as a reliable monitoring system / A. Gheitasi, Mahmoud Moghavvemi and Rosli Omar.
Journal of Electrical and Electronic Systems Research (JEESR), 1: 3.
pp. 23-30.
ISSN 1985-5389
Official URL: https://jeesr.uitm.edu.my/v1/
Abstract
The strategy of Motor current signature has widely been used in industry to diagnose motors faulty conditions. This strategy has some shortcomings that limit it as an engineering auxiliary tool. The main problem of this strategy is its low reliability that in fault diagnosis. In this paper feasibility of application of MCSA as an automatic protection system is investigated and a new online diagnosis strategy is proposed, implemented and initially simulated to apply as an automatic system in motors fault diagnosis.
Metadata
Item Type: | Article |
---|---|
Creators: | Creators Email / ID Num. Gheitasi, A. gheitasi@gmail.com Moghavvemi, Mahmoud Mahmoud@um.edu.my Omar, Rosli rosli_omar@um.edu.my |
Subjects: | T Technology > TK Electrical engineering. Electronics. Nuclear engineering > Electric power distribution. Electric power transmission |
Divisions: | Universiti Teknologi MARA, Shah Alam |
Journal or Publication Title: | Journal of Electrical and Electronic Systems Research (JEESR) |
UiTM Journal Collections: | UiTM Journal > Journal of Electrical and Electronic Systems Research (JEESR) |
ISSN: | 1985-5389 |
Volume: | 1 |
Page Range: | pp. 23-30 |
Keywords: | Motor current; auxiliary tool; motors fault diagnosis |
Date: | June 2008 |
URI: | https://ir.uitm.edu.my/id/eprint/61846 |