Abstract
The purpose of this study is to determine the concentration of the selected elemental composition in a multi-storey hostel. Dust samples were taken from three random rooms at each level of the student hostel by sweeping the floor. The concentrations of elements (Cd, Cu, Fe, Pb and Zn) were determined by using Inductively Coupled Plasma-Optical Emission Spectrometer (ICPOES) after digestion with nitric acid and sulfuric acid solutions. Dust samples analysis has shown the different levels of sampling point does not affect the concentration of the elements. The concentration of elements in investigated microenvironment was in the order of Fe > Zn > Cu > Pb > Cd. The correlation analysis was applied to elements variable in order to identify the sources of an airborne contaminant. It was discovered the strong positive correlation between Cu-Zn which indicates the sources come from traffic emission and street dust. This result was supported by the Principal Component Analysis (PCA) that revealed the presence of elements in the student hostel originated from the outdoor sources.
Metadata
Item Type: | Article |
---|---|
Creators: | Creators Email / ID Num. Mohd Yasim, Nurzulaifa Shaheera Erne nurzulaifa@salam.uitm.edu.my Mat Yaacob, Siti Khadijah UNSPECIFIED Mohamed, Noradila UNSPECIFIED |
Subjects: | T Technology > TD Environmental technology. Sanitary engineering > Air pollution and its control > Indoor air pollution. Including indoor air quality |
Divisions: | Universiti Teknologi MARA, Shah Alam > Faculty of Applied Sciences |
Journal or Publication Title: | Science Letters (ScL) |
UiTM Journal Collections: | UiTM Journal > Science Letters (ScL) |
ISSN: | (eISSN): 2682-8626 |
Volume: | 12 |
Number: | 2 |
Page Range: | pp. 28-36 |
Keywords: | indoor air pollution, multi-storey hostel, element, ICP-OES, PCA |
Date: | 1 December 2018 |
URI: | https://ir.uitm.edu.my/id/eprint/61361 |