Numerical study on seismic responses for high rise building by different positions of water tanks as multiple tuned liquid damper / Izzul Syazwan Ishak

Ishak, Izzul Syazwan (2021) Numerical study on seismic responses for high rise building by different positions of water tanks as multiple tuned liquid damper / Izzul Syazwan Ishak. PhD thesis, Universiti Teknologi MARA.

Abstract

For a country like Malaysia which located at stable Sunda Shelf, an earthquake event is an unthinkable, however at end of year 2002, Sumatra earthquake had caused a panic to lot of people in Penang with few buildings were damages. Majority old high-rise building in Malaysia was not design for earthquake but equip with water tanks. Thus, the main objective of this study is to find the ideal location and water level of tuned liquid damper (water tanks) that give optimum structural response reduction during Southern Sumatra earthquake. The key research for this thesis is numerical analysis using SAP2000, but two shaking table experiments were performed for validation purposes of software modelling. Artificial Neural Networks are utilized to simulate human decision-making abilities to predict new desire output which is based on past input and output data. Three parameters were considered which are mass ratio, depth ratio and water tanks positions. From the shaking table test results, it was found that there is no arrangement of Multiple Tuned Liquid Damper that performs better at all motion levels. In terms of overall performance, however, arrangement 2 is preferred. This study also highlights three different heights of high-rise reinforced concrete structures which are 10, 15 and 20 storey high in order to see the relationship between building height and water tanks position during earthquake excitation. Results shows each position of water tanks will gave a different response reduction depending on the height of building. This indicate that multiple water tanks capable to reduce the structure response during earthquake excitation by adjusting water level and its setup location. Artificial Neural Network predicted 25 storey high based on the input and output gathered in SAP2000. According to Artificial Neural Network, a 25-story height filled with only 1/4 of water has the lowest acceleration reaction. As a result, in areas with low seismic activity, such as Malaysia, where these water tanks serve a function other than just water storage, multiple water tanks can be considered cost-effective as a passive damper.

Metadata

Item Type: Thesis (PhD)
Creators:
Creators
Email / ID Num.
Ishak, Izzul Syazwan
2015793219
Contributors:
Contribution
Name
Email / ID Num.
Thesis advisor
Mohd Amin, Norliyati (Ts. Dr.)
UNSPECIFIED
Subjects: Q Science > QE Geology > Earthquake hazard analysis
Divisions: Universiti Teknologi MARA, Shah Alam > College of Engineering
Programme: Doctor of Philosophy (Civil Engineering)
Keywords: Seismic; seismology; earthquake loading; protection system; tuned liquid damper
Date: September 2021
URI: https://ir.uitm.edu.my/id/eprint/61014
Edit Item
Edit Item

Download

[thumbnail of 61014.pdf] Text
61014.pdf

Download (39kB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:

ID Number

61014

Indexing

Statistic

Statistic details