Evaluation of radiation dose and image quality of CT imaging for different phantom sizes / Nik Norhasrina Nik Din

Nik Din, Nik Norhasrina (2021) Evaluation of radiation dose and image quality of CT imaging for different phantom sizes / Nik Norhasrina Nik Din. Masters thesis, Universiti Teknologi MARA.

Abstract

Worldwide, the number of Computed Tomography (CT) examinations performed is increasing. An initiative was issued by the Food and Drug Administration (FDA) in 2010 to reduce unnecessary radiation exposure from CT imaging. This study aims to evaluate the effect of low tube voltage on radiation dose and image quality using CTDI phantom. The CTDI phantom was scanned with dual-energy CT at 80 kV and 120 kV with the tube current from 150 mAs to 350 mAs. Pitch value was 1.0 while the slice thickness was 1 mm and 5 mm. Results showed that the signal to noise ratio (SNR) values increased when mAs increased. The 5 mm slice thickness showed higher SNR value compared to 1 mm slice thickness. As the tube voltage and tube current increased, the amount of dose absorbed also increased as the current is proportional to a photon flux. Though, the optimal image quality still can be achieved with the reduction of voltage and current to 80 kVp and 300 mAs as well due to reducing unnecessary radiation. However, the radiation dose in pediatric head Computed Tomography examination was reported that decreasing tube voltage in CT examination could reduce the dose to patients significantly. A head phantom was scanned with dual-energy CT at 80 kV and 120 kV. The tube current was set using automatic exposure control mode and manual setting. The pitch was adjusted to 1.4, 1.45 and 1.5 while the slice thickness was set at 5 mm. The dose was measured based on the CT Dose Index (CTDI). Results from this study have shown that the image noise increases substantially with low tube voltage. The dose increases up to 17.19 mGy when the CT tube voltage increases to 120 kV. With the reduction of tube voltage from 120 kV to 80 kV, the radiation dose can be reduced by 12.1% to 15.1% without degradation of contrast-to-noise ratio.

Metadata

Item Type: Thesis (Masters)
Creators:
Creators
Email / ID Num.
Nik Din, Nik Norhasrina
2014715415
Contributors:
Contribution
Name
Email / ID Num.
Thesis advisor
Abdul Rahman, Ahmad Taufek (Assoc. Prof. Dr.)
UNSPECIFIED
Thesis advisor
Rafidah Zainon (Dr.)
UNSPECIFIED
Subjects: R Medicine > RC Internal Medicine > Neoplasms. Tumors. Oncology > Examination. Diagnosis > Magnetic resonance imaging
Divisions: Universiti Teknologi MARA, Shah Alam > Faculty of Applied Sciences
Programme: Master of Science (Applied Physics)
Keywords: Evaluation; radiation; dose; image; quality; CT imaging; different; phantom sizes
Date: January 2021
URI: https://ir.uitm.edu.my/id/eprint/59721
Edit Item
Edit Item

Download

[thumbnail of 59721.pdf] Text
59721.pdf

Download (662kB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:

ID Number

59721

Indexing

Statistic

Statistic details