Indoor Air Quality and Its Relationship to Sick Building Syndrome among Office Workers at Tower 1, PETRONAS, KLCC / Jaharudin Juhan

Juhan, Jaharudin (2011) Indoor Air Quality and Its Relationship to Sick Building Syndrome among Office Workers at Tower 1, PETRONAS, KLCC / Jaharudin Juhan. [Student Project] (Unpublished)

Abstract

A cross-sectional study was conducted in office building at Tower 1, PETRONAS KLCC from November 2010 until December 2010. The main objective of this study was to investigate the association between sick building syndrome (SBS) and indoor air pollutant (IAP) in three different location of office building. A total of 100 office workers from purposive floor were selective as respondents and 54 air sampling location include in this study. All the IAP measured below the maximum limit and complies with Industrial Code of Practice on Indoor Air Quality 2010, DOSH. ANOVA test found there are significant different of Carbon Monoxide (p<0.001) in each location, while Kruskall Wallis found Air Movement (P<0.001) is significant different in each location. Sick Building Syndrome (SBS) shows the increasing with the floor heights. 6 SBS prevalence found significant among three different location as 'dry, itching, or irritated eyes' (p=0.001 ), 'sore or dry throat' (p=0.004), 'stuffy or runny nose or sinus congestion' (p=0.002), 'difficult remembering' (p=0.004), 'dizziness or light headed' (p=0.005), and 'dry or itchy skin' (p=0.002). CO, temperature, and air movement statistical found correlate to SBS. The Pearson Correlation test showed that there was significant correlation between Temp. and 'dry, itching, or irritated eyes' (r = 0.370, P = 0.006), 'headaches' (r = 0.375, P = 0.005), 'sore or dry throat' (r = 0.327, P=0.016), 'unusual tiredness, fatigue' (r = 0.326, P = 0.016), and difficult remembering (r = 0.389, P=0.004), while Air movement found significant with 'dry, itching, or irritated eyes' (r = 0.271, P =0.047). Spearman Correlation was test on CO parameter with SBS, and the result is significant between CO and 'dry or itchy skin' (r = 0.306, P = 0.025). As a conclusion, this study found there are significant different of indoor air pollutant in each location, SBS prevalence show the increasing with the floor heights, and statistical analysis found there is correlation between CO, temperature and air movement with SBS symptom.

Metadata

Item Type: Student Project
Creators:
Creators
Email / ID Num.
Juhan, Jaharudin
2008393583
Contributors:
Contribution
Name
Email / ID Num.
Thesis advisor
Mohd Yatim, Siti Rohana
UNSPECIFIED
Thesis advisor
mohd Tahir, Pozi
UNSPECIFIED
Subjects: T Technology > TD Environmental technology. Sanitary engineering > Special types of environment. Including soil pollution, air pollution, noise pollution
T Technology > TD Environmental technology. Sanitary engineering > Air pollution and its control
Divisions: Universiti Teknologi MARA, Selangor > Puncak Alam Campus > Faculty of Health Sciences
Programme: Bachelor in Environmental Health and Safety
Keywords: Indoor Air Quality, Sick Building Syndrome, Indoor Air Pollutants
Date: 2011
URI: https://ir.uitm.edu.my/id/eprint/54626
Edit Item
Edit Item

Download

[thumbnail of 54626.PDF] Text
54626.PDF

Download (313kB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:

ID Number

54626

Indexing

Statistic

Statistic details