Indoor Air Quality and Its Relationship to Sick Building Syndrome among Office Workers at Tower 1, PETRONAS, KLCC / Jaharudin Juhan

Juhan, Jaharudin (2011) Indoor Air Quality and Its Relationship to Sick Building Syndrome among Office Workers at Tower 1, PETRONAS, KLCC / Jaharudin Juhan. [Student Project] (Unpublished)
Abstract

A cross-sectional study was conducted in office building at Tower 1, PETRONAS KLCC from November 2010 until December 2010. The main objective of this study was to investigate the association between sick building syndrome (SBS) and indoor air pollutant (IAP) in three different location of office building. A total of 100 office workers from purposive floor were selective as respondents and 54 air sampling location include in this study. All the IAP measured below the maximum limit and complies with Industrial Code of Practice on Indoor Air Quality 2010, DOSH. ANOVA test found there are significant different of Carbon Monoxide (p<0.001) in each location, while Kruskall Wallis found Air Movement (P<0.001) is significant different in each location. Sick Building Syndrome (SBS) shows the increasing with the floor heights. 6 SBS prevalence found significant among three different location as 'dry, itching, or irritated eyes' (p=0.001 ), 'sore or dry throat' (p=0.004), 'stuffy or runny nose or sinus congestion' (p=0.002), 'difficult remembering' (p=0.004), 'dizziness or light headed' (p=0.005), and 'dry or itchy skin' (p=0.002). CO, temperature, and air movement statistical found correlate to SBS. The Pearson Correlation test showed that there was significant correlation between Temp. and 'dry, itching, or irritated eyes' (r = 0.370, P = 0.006), 'headaches' (r = 0.375, P = 0.005), 'sore or dry throat' (r = 0.327, P=0.016), 'unusual tiredness, fatigue' (r = 0.326, P = 0.016), and difficult remembering (r = 0.389, P=0.004), while Air movement found significant with 'dry, itching, or irritated eyes' (r = 0.271, P =0.047). Spearman Correlation was test on CO parameter with SBS, and the result is significant between CO and 'dry or itchy skin' (r = 0.306, P = 0.025). As a conclusion, this study found there are significant different of indoor air pollutant in each location, SBS prevalence show the increasing with the floor heights, and statistical analysis found there is correlation between CO, temperature and air movement with SBS symptom.

Item Details
Edit Item
Edit Item
Downloads & Files
[thumbnail of 54626.PDF]
Text
54626.PDF
Download (313kB)
Location & Physical Holdings
Digital Copy
Physical Location
  • Bilik Koleksi Harta Intelek, Unit Terbitan Bersiri dan Elektronik | PTAR Puncak Alam
Item Status
Indexing & Metrics