Building related illness has still not gained the same prominence as those related to outdoor air quality. As such Malaysia definitely needs to identify and highlight the importance of the impact of indoor air quality on health as it is believed that residents in urban areas spend 90% of their time indoor. The study was conducted in health center located in MARA University of Technology, Shah Alam, Selangor. The study design of this study is cross-sectional study and evaluation the health problems of the occupants related to indoor air quality. Sampling data collection using QUESTemp⁰ 36; Area Heat Stress and Thermal Comfort monitor, Gas Alert Micro 5 IR (1, 2, 3, 4 and 5 gas detector), BW Technologies by Honeywell International Ltd and modified Industry Code of Practice on Indoor Air Quality, Department of Occupational, Safety and Health questionnaire. A statistical analysis that is statistical package for the social science (SPSS) version 19.0 was used in this study. The study found that the reading of the sampled parameters carbon monoxide (0.123 ppm), carbon dioxide (2030 ppm), temperature (25.9°C), air velocity (0.09 mis) and relative humidity (56.8%). Carbon dioxide is the only reading that exceeds the permissible limit with 2030 ppm. The respondent has experienced the symptoms of sick building syndrome, headache (83.1%), thick-witted (64.6%), fatigue or lethargic (70.8%), sleepy (78.5%), dizziness (55.4%), nausea or vomiting (23.1%), cough (55.4%), stuffy nose (58.5%), dry throat (61.5%), skin rash or itchiness (33.8%), initiation of the eyes (26.2%) and itching scalp or ears (33.8%). The CO2 concentration was the only parameter that has violation but others was below the acceptable limit. From the results by using Pearson Correlation between work environment and Sick Building Syndrome symptoms, there was 0.763 where is significant at the 0.01 level (2-tailed). It shows there was a strong relationship between work environment and diseases or symptoms.

Metadata

Item Type: Student Project
Creators:
Creators
Email / ID Num.
Moktar, Khairul Anam
2007238428
Contributors:
Contribution
Name
Email / ID Num.
Thesis advisor
Dal, Abd Rahim
UNSPECIFIED
Subjects: R Medicine > RA Public aspects of medicine > Public health. Hygiene. Preventive Medicine > Environmental health. Including sewage disposal, air pollution, nuisances, water supply
T Technology > TD Environmental technology. Sanitary engineering > Special types of environment. Including soil pollution, air pollution, noise pollution
T Technology > TD Environmental technology. Sanitary engineering > Air pollution and its control > Indoor air pollution. Including indoor air quality
Divisions: Universiti Teknologi MARA, Selangor > Puncak Alam Campus > Faculty of Health Sciences
Programme: Bachelor in Environmental Health and Safety
Keywords: Building related illness, Indoor Air Quality, Sick Building Syndrome, acceptable limit.
Date: May 2011
URI: https://ir.uitm.edu.my/id/eprint/52415
Edit Item
Edit Item

Download

[thumbnail of 52415.PDF] Text
52415.PDF

Download (1MB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:

ID Number

52415

Indexing

Statistic

Statistic details