Indoor air quality in selected childcare centers in Klang, Selangor / Mohd Rikyhanas Mohd Nasir

Mohd Nasir, Mohd Rikyhanas (2013) Indoor air quality in selected childcare centers in Klang, Selangor / Mohd Rikyhanas Mohd Nasir. Degree thesis, Universiti Teknologi MARA ( Kampus Puncak Alam ).

Abstract

A comparative cross sectional study on selected· pollutant concentration level of PM₁₀, C02 and CO, and physical air quality parameters such as ambient temperature and relative humidity between 15 selected childcare centers that is categorized by area (residential, urban and industrial) in Klang, Selangor. Objective of the study is to determine the indoor air quality in selected childcare centers in Klang, Selangor. The level of air pollutant (C02 and CO) concentration and physical air quality parameters (ambient temperature and relative humidity) have been measured using EVM 7 for outdoor and IAQ meter for indoor environments. Air movements or velocity was measured using kestrel 10.00 anemometer. For PM₁₀, Dust Trak 2 have been used both for indoor and outdoor environments. Walkthrough assessments have been held before conducting the study in order to determine suitable sampling points and details of childcare centers have been noted. The different concentration and correlation of air pollutants, physical air quality parameters were analyzed using SPSS for statistical analysis. The acceptable limit of physical and chemical air parameters was based on Industrial Code of Practice on Indoor Air Quality by Department of Occupational Safety and Health, Malaysia (DOSH). Result showed that, the mean concentration of ambient temperature in each area (residential, urban and industrial) were exceeding the standard limits of Code of Practice on Indoor Air Quality 2010 by DOSH, whereas for relative humidity and air movements, the mean concentration for each area are complying with the standard limits. For indoor air pollutant concentration measurements, only PM₁₀ level in industrial area is exceeding the standard limit given, while measurement in each areas for C02 and CO were both complying with the standard limits. There is a significant difference between C02 and air movement between indoor and outdoor measurement in residential area. For Urban area, there is significant difference of relative humidity, C02 and air movement between indoor and outdoor mean concentration while in industrial area, there are no significance different. The exposure dose for particulate matter, PM10 in residential area is 0.023 (m/g)/kg, in urban area is 0.044 (mg/kg)/day whereas for industrial area, it is the highest with 0.078 (mg/kg)/day. As a conclusion, there afe a few parameters of physical air and selected pollutant concentration levels were exceeding the standard limits in residential, urban or industrial areas. There also a significantly differences between indoor and outdoor concentration of pollutants such as relative humidity, air movements and carbon dioxide. The exposure dose calculated for child in industrial childcare centers recorded as the highest compare to residential and urban areas.

Metadata

Edit Item
Edit Item

Download

[thumbnail of 44145.PDF] Text
44145.PDF

Download (2MB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:

ID Number

44145

Indexing

Statistic

Statistic details