Abstract

Adulteration is a major concern in religion and health. In this study, palm oil was used as it is one of the world most frequent used cooking oil. Near infrared spectroscopy technique is a reliable method to detect adulteration in cooking oil due to less sample preparation, rapid scan and applicable on on-site. Short wave near infrared spectroscopy (NIR) method was implemented in this experiment to detect the presence of lard adulteration in palm oil. MicroNIR was set up in two different scan modes to study the effect of path length to the performance of spectral measurement. Pure and adulterated palm oil sample were classified using soft independent modeling class analogy (SIMCA) algorithm with model accuracy more than 0.95 reported for both transflectance and transmission modes. Additionally, by employing partial least square (PLS) regression, the coefficient of determination (R2 ) of transflectance and transmission were 0.9987 and 0.9994 with root mean square error of calibration (RMSEC) of 0.5931 and 0.6703 respectively. In order to remove the uninformative variables, cumulative adaptive reweighted sampling (CARS) has been performed. The result of R2 and RMSEC after variable selection for transflectance and transmission were improve significantly. Based on the result of classification and quantification analysis, the transmission mode has yield better prediction model compared to the transflectance mode. Based on the critical wavelength obtained in CARS, 1200 nm and 1450 nm LED were chosen to replace the halogen tungsten as a light source for the NIR spectrometer. Using LED, the model accuracy obtained to detect pure palm oil is 0.99 which shows the classification result for LED is better compared using halogen tungsten light source. R2 acquired of PLS model for LED is 0.9970 for calibration and 0.9962 for prediction. RMSEC and RMSEP value are 0.8886 and 1.0173. For quantification analysis, the results of LED and halogen tungsten light source were on par.

Metadata

Item Type: Thesis (Masters)
Creators:
Creators
Email / ID Num.
Basri, Katrul Nadia
2014814036
Contributors:
Contribution
Name
Email / ID Num.
Thesis advisor
Zoolfakar, Ahmad Sabirin
UNSPECIFIED
Thesis advisor
Sharif, Zaiton
UNSPECIFIED
Subjects: S Agriculture > SB Plant culture > Field crops > Oil-bearing plants. Wax plants
T Technology > T Technology (General) > Technological change
Divisions: Universiti Teknologi MARA, Shah Alam > Faculty of Electrical Engineering
Programme: Master of Science
Keywords: Palm oil, NIR, LED
Date: 2017
URI: https://ir.uitm.edu.my/id/eprint/37198
Edit Item
Edit Item

Download

[thumbnail of 37198.pdf] Text
37198.pdf

Download (172kB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:
On Shelf

ID Number

37198

Indexing

Statistic

Statistic details