Finger exoskeleton for early acute stroke rehabilitation: control design and performance analysis / Muhammad Naim Abdu Salam

Abdu Salam, Muhammad Naim (2020) Finger exoskeleton for early acute stroke rehabilitation: control design and performance analysis / Muhammad Naim Abdu Salam. Masters thesis, Universiti Teknologi MARA.

Abstract

The number of stroke patients suffering from upper extremity hemiparesis increases from year to year. Manual repetitive therapy applied to stroke patients by trained therapists is limited by the number of therapists available. Many types of rehabilitation devices are invented to help patients recover their hand functions including exoskeleton devices. These devices can deliver high intensity therapy for a longer period of time. Every exoskeleton rehabilitation device is made up of three components: exoskeleton mechanism, actuator and control system. Control system is central to rehabilitation devices. The accurate control algorithm implementation is very crucial for the rehabilitation aspect. The performance of the control algorithm for rehabilitation must be investigated to assess the efficiency of the devices for rehabilitation. This research aimed to apply different Proportional Integral and Derivative (PID) controller configurations for position control of the index finger exoskeleton in rehabilitation. The second objective was to assess the performance of position control for index finger in rehabilitation. The control algorithm utilized was PID control algorithm. The parameter controlled was position of index finger measured through Metacarpophalangeal (MCP) joint angle. PID parameters were tuned using heuristic method and Ziegler Nichols’ closed loop method. In order to assess the performance of the control system, desired or reference values were used. The actual data from position control were compared to reference values to investigate the performance. This study suggested that the PID controller managed to control the parameter according to the set point better than Proportional (P), Proportional and Integral (PI), and Proportional and Derivative (PD) controllers. The device could be manipulated to move to any position within the range of exoskeleton motion accurately. The results of the study also suggested that the performance of the control system for rehabilitation was very good as the error (difference between actual value and reference value) was less than 10%. Hence, the objectives of the research project were successfully achieved.

Metadata

Item Type: Thesis (Masters)
Creators:
Creators
Email / ID Num.
Abdu Salam, Muhammad Naim
2017986763
Contributors:
Contribution
Name
Email / ID Num.
Thesis advisor
Ab Patar, Mohd Nor Azmi (Dr.)
UNSPECIFIED
Subjects: Q Science > QA Mathematics > Instruments and machines > Electronic Computers. Computer Science > Computer simulation
Q Science > QA Mathematics > Instruments and machines > Electronic Computers. Computer Science > Interactive computer systems
Divisions: Universiti Teknologi MARA, Shah Alam > Faculty of Mechanical Engineering
Keywords: stroke, rehabilitation, exoskeleton
Date: March 2020
URI: https://ir.uitm.edu.my/id/eprint/32523
Edit Item
Edit Item

Download

[thumbnail of 32523.pdf] Text
32523.pdf

Download (240kB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:
On Shelf

ID Number

32523

Indexing

Statistic

Statistic details