Abstract
This project implements digital technique to control the inspection wires in pilot cable by using ALTERA Cyclone II board. It is the advancement of time-domain reflection (TDR) technique for faulty cable detection. The TDR module generates pulse signal and it will be injected into the inspection wire. The edge and reflection signal from the inspection pilot cable are recorded by the digital sampling oscilloscope (DSO). By analyzing the shape of reflected pulse signal (in step waveform) and other data using oscilloscope, the type and location of fault cable can be determined. This entire module is coded using Very High Speed Integrated Circuit Hardware Description Language (VHDL).
Metadata
Item Type: | Student Project |
---|---|
Creators: | Creators Email / ID Num. Mohd Rodzi, Mohamad Zarifi 2006135079 |
Contributors: | Contribution Name Email / ID Num. Advisor Saparon, Azilah UNSPECIFIED |
Subjects: | T Technology > TK Electrical engineering. Electronics. Nuclear engineering > Electromagnetic fields |
Divisions: | Universiti Teknologi MARA, Shah Alam > Faculty of Electrical Engineering |
Programme: | Bachelor of Electrical Engineering (Hons) |
Keywords: | Time-domain reflection, pilot cable, transmission line |
Date: | 2009 |
URI: | https://ir.uitm.edu.my/id/eprint/103032 |