Abstract
For most storage tanks it is necessity to provide a roof cover to protect the contents from contamination. In some cases additional insulation from the atmosphere is provided by covering. So it is not main structures of storage tank . The cost of this roof will amount generally to about one - third of the overall cost of the structure and considerable care is required in making a choice of form and method of construction to employ the most economical solution appropriate to the particular project. In this work finite element analysis approach is employed to study the strength of the regular shape of water tank under concentrated loads. It is intended to check the strength based on the load displacement relationships. To simulate the process, several application software can be used .in this study ANSYS version 5.0 is adopted to three computer model of Cone , Dome, and Flat with equal radius, thickness and height. The height is 300 mm, radius is 3000 mm and the thickness is 15mm under 1 loading point of 2 KN. From the finite element analysis, the result showed more different strength behaviour between different type of material
Metadata
Item Type: | Thesis (Degree) |
---|---|
Creators: | Creators Email / ID Num. Sidik, Mohd Hamdi UNSPECIFIED |
Contributors: | Contribution Name Email / ID Num. Thesis advisor Wan Abdul Majid, Wan Mahmood UNSPECIFIED |
Divisions: | Universiti Teknologi MARA, Shah Alam > Faculty of Civil Engineering |
Programme: | Bachelor in Engineering (Civil) |
Date: | 1998 |
URI: | https://ir.uitm.edu.my/id/eprint/100807 |
Download
100807.pdf
Download (103kB)