Seismic performance of precast shear-key wall panel of single bay double story house under quasi-static lateral cyclic loading / Nor Mayuze Mohamad

Mohamad, Nor Mayuze (2014) Seismic performance of precast shear-key wall panel of single bay double story house under quasi-static lateral cyclic loading / Nor Mayuze Mohamad. Masters thesis, Universiti Teknologi MARA.

Abstract

A full-scale of single bay double storey house (5.1m x 4.5m x 3.9m) was constructed using precast shear wall panel and cast-in situ wet connection at Construction Research Institute of Malaysia (CREAM), Malaysia. This type of building was designed using BS8110 which did not have any provision for seismic loading and no detailing of its connection. The aim of this study is to determine the global seismic behaviour of non-ductile double storey house under quasi-static lateral cyclic loading. This research work involves two main phases. The first phase includes design of double storey residential house, the construction of a full-scale prototype of double-storey residential house using precast wall panel, experimental set-up and calibration of instruments and testing of the specimen. The second phase includes the modeling of prototype using Ruaumoko programming. Two actuators were attached to the shear wall to simulate the lateral cyclic loading. Fourteen (14) linear potentiometers and twenty six (26) strain gauges were used to measure lateral displacement of precast wall panels and strain in steel and concrete. The maximum strength capacity of WALL1 is 244.27kN with lateral displacement of 18mm. A lot of cracks were observed at wet connections between wall and column and wall-beam interfaces. The building was started to loss its strength (strength degradation) at 0.5% drift and became unstable at 0.7% drift where the biggest opening of crack with 16.10mm was observed at wall-column interface. By using three chosen earthquake excitation, the mode shape, natural period and natural frequency are determined, followed by nodal displacement and positional drift were compared. All of the earthquakes have a similar value of force and the maximum values of these forces are axial forces, 442.2 kN, moment, 419.3kNm and shear force, 301.6 kN. In general, this type of building can only survive under low magnitude of earthquake loading and long distantearthquakes centered in Sumatra.

Metadata

Item Type: Thesis (Masters)
Creators:
Creators
Email / ID Num.
Mohamad, Nor Mayuze
UNSPECIFIED
Subjects: T Technology > TA Engineering. Civil engineering > Structural engineering
Divisions: Universiti Teknologi MARA, Shah Alam > Faculty of Civil Engineering
Programme: Master of Science (Civil Engineering)
Keywords: shear; precast; seismic
Date: 2014
URI: https://ir.uitm.edu.my/id/eprint/16380
Edit Item
Edit Item

Download

[thumbnail of TM_NOR MAYUZE MOHAMAD EC 14_5.pdf] Text
TM_NOR MAYUZE MOHAMAD EC 14_5.pdf

Download (1MB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:

ID Number

16380

Indexing

Statistic

Statistic details