The electrochemical behaviour of metallic biomaterials in simulated human body fluid / Ain Athirah Rozali

Rozali, Ain Athirah (2021) The electrochemical behaviour of metallic biomaterials in simulated human body fluid / Ain Athirah Rozali. Masters thesis, Universiti Teknologi MARA.

Abstract

The improvement of bio-implant applications in biomedical field grows together with the introduction of recently developed metals and alloys as bio-implant materials. However, the main concern for using metal alloy as an implantation is their tendency to corrode in physiological environment in the human body. Human body environment presents a corrosive that may lead to the rejection or implant failures. Therefore, the selection of most suitable implant material that is accepted by the living tissues is the major criteria to be focused on. Titanium, stainless steel and nickel titanium as basic metals were used in this study. The electrochemical tests performed in this study were open circuit potential (OCP) and potentiodynamic polarization on Ti-6Al-4V, 316L SS and Nitinol. These tests were performed with and without the addition of bovine serum albumin (BSA) to the phosphate buffer solution (PBS) with pH values of 5.2 and pH 7.4 at 37˚C. The results showed that the corrosion potential (Ecorr) of 316L SS with the presence of BSA at both pH values are higher (pH 5.2= -652.0 mV, pH 7.4= -818.0 mV) than with no addition of BSA. Meanwhile, the corrosion resistance of Ti-6Al-4V at pH 7.4 and Nitinol at pH 5.2 increased without presence of BSA. The corrosion behaviour of Ti-6Al-4V, 316L SS and Nitinol under the concentrations of 0%, 2%, 4%, 6%, 8% and 10% of BSA at 37˚C were investigated using electrochemical methods. For Ti-6Al-4V, the potentiodynamic polarization graph showed the formation of TiO2 layers are most stable in solutions that contain 0%, 2% and 8% of BSA. Meanwhile, the highest Ecorr happened to 316L SS in the 8% of BSA. This shows that at 8% BSA, the proteins are most effective to decrease the corrosion rate of 316L SS by acting as a protective barrier from the initial stages of corrosion. For Nitinol in the solutions without proteins is most effective to decrease the corrosion rate of Nitinol alloy with the formation of TiO2 layer at the initial stages of corrosion. By analyzing electrochemical impedance spectroscopy (EIS) measurements for Ti-6Al-4V and 316L SS, it can be seen that the most stable film formed on both alloys are in the solution that contain 8% of BSA. For Nitinol, at high impedance results indicated that all BSA concentrations showed almost similar behaviour which 0%, 2% and 4% followed by 8%, 10% and 6%, as the frequencies increases from −2 Hz to closely 6 Hz. From the equivalent circuit parameter, Nitinol alloy best perform with the presence of lower BSA (2% and 4%). All the three alloys were observed under scanning electron microscope (SEM) in order to analyze the changes in their surface morphology before and after the electrochemical tests. The brown colour appeared on the surface of samples were natural reaction to metal corrosion. The white products produced were due to the protein that adsorbed on the metal surface. 2D Raman spectroscopy is displayed as a contour map that allowed for the selection of an optimal time of conformational stability of proteins adsorption on the surface of the implant. It reveals that albumin in contact with the surface of Ti-6Al-4V surface after 30 minutes in BSA, while 316L SS and Nitinol took 60 minutes. Human serum albumin (HSA) achieves a stable configuration after only 15 minutes for Ti-6Al-4V, while 316L SS and Nitinol after 40 minutes resulted the time differences between both types of protein.

Metadata

Item Type: Thesis (Masters)
Creators:
Creators
Email / ID Num.
Rozali, Ain Athirah
2015506857
Contributors:
Contribution
Name
Email / ID Num.
Thesis advisor
Nik Masdek, Nik Rozlin (Dr.)
UNSPECIFIED
Subjects: T Technology > TJ Mechanical engineering and machinery > Mechanical and electrical engineering combined
Divisions: Universiti Teknologi MARA, Shah Alam > Faculty of Mechanical Engineering
Programme: Master of Science (Mechanical Engineering)
Keywords: Metallic biomaterials; electrochemical behaviour; biological environment; biomedical implant
Date: September 2021
URI: https://ir.uitm.edu.my/id/eprint/60086
Edit Item
Edit Item

Download

[thumbnail of 60086.pdf] Text
60086.pdf

Download (277kB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:

ID Number

60086

Indexing

Statistic

Statistic details