Abstract

This thesis is focused on the Development and Fabrication of the Piezoresistive Microcantilever-based Glucose Biosensor. The objective of this work is to design via simulation a piezoresistive microcantilever sensor suitable for glucose sensing. Then, the piezoresistive microcantilever is fabricated with CMOS micromacriining technique. The fabricated piezoresistive microcantilever performed the fabrication process characterization to prove the viability of the design. Finally, the objective in this work is to identify suitable Glucose immobilization technique onto microcantilever surface. The methodology of this work starts with the designing of piezoresistive microcantilever. The microcantilever beam length is selected at 195um and width, 70um. On this microcantilever beam there are four different piezoresistor with the length of 80um, HOum, 140um and 170um. The sacrificial layer of BPSG material in the piezoresistive microcantilever have two different thickness of 0.9um and 1.8um.The proposed biosensor also includes the fabrication process design and the process characteristic study such as the resistivity testing and wet etching characteristic study with wet etchant of Hydrofluoric (HF) acid, Pad Etchant and Buffered Oxide Etch (BOE) to observe the etching rate of the BPSG sacrificial layer. This investigation is important to observe the performance of the MEMS biosensor. Then, the signal conditioning circuit is developed to convert the physical behavior of the piezoresistive microcantilever to electrical signal. The signal conditioning circuit includes the wheatstone bridge, amplification, filtering and linearization circuitry. The next step is the investigation of several Glucose Oxidase (GOx) immobilization techniques on the fabricated microcantilever biosensor surface to find out the optimal enzyme immobilization. In this work there are two controlled conditions which is the glucose testing on the blank piezoresistive microcantilever and other is glucose testing on piezoresistive microcantilever immobilized without Glucose Oxidase (GOx). The proposed glucose-based MEMS biosensor has been developed and tested. The measurement obtained shows that at the testing of the glucose with blank microcantilever no resistance changes are observed indicates that no immobilization of receptor occurs with this technique. In the second method, the immobilization technique used normally is for the Au coated silicon microcantilever investigated previously by Jianhong et al. With this technique, GOx immobilized PZR microcantilever sensor found there is a resistance change caused by a change in surface stress in response to the microcantilever deflection. The measurement obtained shows the possibility use of piezoresistive microcantilever for glucose testing.

Metadata

Item Type: Thesis (PhD)
Creators:
Creators
Email / ID Num.
Madzhi, Nina Korlina
2006651962
Contributors:
Contribution
Name
Email / ID Num.
Thesis advisor
Lee, Yoot Khuan
UNSPECIFIED
Subjects: T Technology > T Technology (General) > Technological change > Technological innovations
T Technology > TK Electrical engineering. Electronics. Nuclear engineering > Electronics > Detectors. Sensors. Sensor networks
Divisions: Universiti Teknologi MARA, Shah Alam > Faculty of Electrical Engineering
Programme: Doctor of Philosophy
Keywords: Biosensor technology, piezoresistive microcantilever, Glucose Oxidase (GOx)
Date: 2011
URI: https://ir.uitm.edu.my/id/eprint/41269
Edit Item
Edit Item

Download

[thumbnail of 41269.pdf] Text
41269.pdf

Download (185kB)

Digital Copy

Digital (fulltext) is available at:

Physical Copy

Physical status and holdings:
Item Status:
On Shelf

ID Number

41269

Indexing

Statistic

Statistic details