Abstract
A reliable procedure for malfunction detection due to excessive vibration is
required especially for equipment that works in a continuous operation. In
this paper, an analytical model to describe the vibration level of a verticaltype centrifugal pump shaft was developed. Based on the developed model,
vibration characteristics of the pump was simulated. It was found that the
pump vibrates at its natural frequency of 15.9 Hz with the amplitude of
0.2903. The tangential forces, as a result of the motor torque, forced the
system to vibrate at a higher frequency of 325 Hz with a higher amplitude of
1. Physical vibration measurement revealed that vibration is primarily
occurred on the vertical axis, in which point 1 recorded a higher level of
vibration as compared to point 2. These procedures allow examination of the
vibration level and primary axis of the vibration in the studied pump system
for further monitoring application and appropriate maintenance action.
Metadata
Item Type: | Article |
---|---|
Creators: | Creators Email / ID Num. Chandra, Hendri hendrichandra09@gmail.com Luthfi, Muhamad Indra UNSPECIFIED Lamin, Fauziana UNSPECIFIED Ariffin, Ahmad Kamal UNSPECIFIED |
Subjects: | T Technology > TJ Mechanical engineering and machinery > Mechanical devices and figures. Automata. Ingenious mechanisms.Robots (General) T Technology > TJ Mechanical engineering and machinery > Hydraulic machinery |
Divisions: | Universiti Teknologi MARA, Shah Alam > Faculty of Mechanical Engineering |
Journal or Publication Title: | Journal of Mechanical Engineering (JMechE) |
UiTM Journal Collections: | UiTM Journal > Journal of Mechanical Engineering (JMechE) |
ISSN: | 18235514 |
Volume: | SI 7 |
Number: | 1 |
Page Range: | pp. 167-175 |
Keywords: | Analytical model; Centrifugal pump; Torsional vibration; Monitoring system; Maintenance |
Date: | 2018 |
URI: | https://ir.uitm.edu.my/id/eprint/41508 |