Abstract

In recent indoor air quality studies, people tend to concern of indoor air quality in schools especially in elementary schools. This was because schools had high density of occupants and majority of them were children. Children were more susceptible to air pollutants and easy to fall sick compared to adults due to their immature organs and developing immune system. This study was focusing on PM 10 and its impacts to building occupants of selected primary schools. Two schools in Kuala Selangor were selected to conduct the study. The equipment used for the study was Qtrak and Dustrak to measure particulate matter (PM₁₀) and carbon dioxide (CO₂). Meteorological data including relative humidity and temperature were also estimated in this study. The data collected five hours of school time period in 21 classrooms and 4 educational rooms. Natural lighting for each class was measured in monitoring light exposure in the selected classrooms and compared to Uniform Building by Law 1984. The average particulate matter reading level for school A and B were 33.69µg m-³ – 92.74 µg m-³ and 28µg m-³ – 116.63µg m-³ which were lower than RMG and NAAQS but exceed the threshold limit of WHO. The range for relative humidity during the study conducted was 63.8% – 81.9% and the range for temperature was 27.6ºC – 31.1ºC. A set of questionnaires adopted from ICOP 2010 were also given out to teachers for both schools. Evaluation of this activity was related to the presentation of Sick Building Syndromes (SBS) in both schools. The comparison in these schools might identify any classrooms with higher particles level and recommendations steps can be applied as to improve the microenvironment thus serve healthier place for building occupants of the schools.

Metadata

Item Type: Student Project
Creators:
Creators
Email
Abd Rashid, Rosella Elina
2014807584
Contributors:
Contribution
Name
Email / ID Num.
Advisor
Shafie, Farah Ayuni
UNSPECIFIED
Subjects: R Medicine > RA Public aspects of medicine > Public health. Hygiene. Preventive Medicine > Environmental health. Including sewage disposal, air pollution, nuisances, water supply
T Technology > TD Environmental technology. Sanitary engineering > Special types of environment. Including soil pollution, air pollution, noise pollution
T Technology > TD Environmental technology. Sanitary engineering > Air pollution and its control > Indoor air pollution. Including indoor air quality
Divisions: Universiti Teknologi MARA, Selangor > Puncak Alam Campus > Faculty of Health Sciences
Programme: Bachelor in Environmental Health and Safety
Item ID: 49300
Uncontrolled Keywords: particulate matter, lighting, temperature, relative humidity
URI: https://ir.uitm.edu.my/id/eprint/49300

Fulltext

Fulltext is available at:
  • Bilik Koleksi Harta Intelek, Unit Terbitan Bersiri & Elektronik, PTAR Puncak Alam
  • ID Number

    49300

    Indexing


    View in Google Scholar

    Edit Item
    Edit Item