Behaviour of profiled steel sheet dry board system as walling unit with door opening / Zaharil Nikman @ Muhammad Arman

Arman, Zaharil Nikman @ Muhammad (2002) Behaviour of profiled steel sheet dry board system as walling unit with door opening / Zaharil Nikman @ Muhammad Arman. Student Project. Faculty of Civil Engineering, Shah Alam. (Unpublished)

[img] Text
PPb_ZAHARIL NIKMAN MUHAMMAD ARMAN EC 02_5.pdf

Download (75kB)

Abstract

The experimental study on the Behaviour of Profiled Steel Sheet Dry Board System (PSSDB) with Door Opening as load bearing wall were carried out. PSSDB is formed by Profiled Steel Sheet (BONDEK II) connected to two the dry boards (CEMBOARD) using self-tapping screws. The study of PSSDB system involved doubleskin composite walling panel. The experiment carried out was to determine the behaviour of this system under axial load. There were four samples tested with and without overlapping of profiled steel sheet. The size of sample was 600mm width and 1000mm height. The size of door opening was 186mm width and 680mm height. The parameters measured and determined were deflections, overall buckling, crushing on panel, Young’s Modulus (E) and ultimate load capacity. From the experiment, load displacement curve and stressstrain relationship were identified. The average ultimate load capacity for the overlap sample was 214kN and the ultimate load capacity for the non-overlap was 138kN.

Item Type: Monograph (Student Project)
Creators:
CreatorsEmail
Arman, Zaharil Nikman @ MuhammadUNSPECIFIED
Divisions: Faculty of Civil Engineering
Item ID: 18133
Uncontrolled Keywords: Profiled steel sheet dry board system; Walling unit
Last Modified: 18 Feb 2019 01:55
Depositing User: Staf Pendigitalan 2
URI: http://ir.uitm.edu.my/id/eprint/18133

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year